HI Maxime
check the aseg labels and make sure they are correct (and fix them if
not). Probably a couple of left/right ventricle voxels are mislabeled
Bruce
On
Fri, 10 Aug 2018, Maxime Perron wrote:
External Email - Use Caution
Hello FreeSurfer Developers,
I use Freesurfer 6 on macOS Sierra 10.12.6. In several subjects, I found
midline cutting error, that
is the midline does not go through exactly the center of the brain in coronal
cut. For example, the
midline is a little bit fuzzy and goes through an hemisphere than the other
(see attachment). I've
searched in the mail list and I don't find the way to fix it. Does anyone have
any idea to fix it?
Thank you,
Maxime Perron