On Tue, Feb 20, 2018 at 8:59 PM, Thomas Koenig <tkoe...@netcologne.de> wrote:
> Am 20.02.2018 um 08:51 schrieb Janne Blomqvist:
>
>> It's better to use gfc_mpz_get_hwi() instead of mpz_get_si().
>> mpz_get_si() returns a long, which is a 32-bit type on win64.
>>
>> Otherwise Ok with the spelling fix suggested by Steve.
>
>
> Committed as r257856.
>
> Thanks to you and Steve for the review and the heads_up about
> gfc_mpz_get_hwi.
>
> I also changed the "call abort" to "STOP 1" at the last second
> (old habits are hard to break, it seems :-)

Shouldn't the second one be "stop 2"?


-- 
Janne Blomqvist

Reply via email to