When we enable JPEG-2000 compression (or any IC=* creation option) alongside 
"SDE_TRE=YES" we get:
"Warning 1: Unable to locate COMRAT to update in NITF header."

We require the precision increase provided by "SDE_TRE=YES" and dropping the IC 
creation option
explodes the size of our final mosaics by an order of magnitude. Using either 
option separately is fine,
however, combining them emits this warning.

For context we are taking GeoTIFF mosaics and converting them to the NITF 
format when we encounter this.

Thanks,
Raymond.
_______________________________________________
gdal-dev mailing list
gdal-dev@lists.osgeo.org
https://lists.osgeo.org/mailman/listinfo/gdal-dev