On 9/23/06, Ramakrishnan Muthukrishnan <[EMAIL PROTECTED]> wrote:

Now, I connected the 'nc' symbol to all the unconnected pins of U102
and those errors vanished. U105 is LM311 symbol from the geda standard
installation and pin 1 of the symbol comes connected to GND. But DRC
complains that it is unconnected? What am I doing wrong here?

There looks there is a mistake in that symbol. Pin one is not really
connected to ground since there is no net connection in that symbol.
The ground is only graphical.

If you connect your system ground to the red dot on pin number one your
error should go away.

In my copy of the symbol the last three line commands draw the ground symbol.
If you remove these lines the symbol should be correct.

(* jcl *)


--
http://www.luciani.org


_______________________________________________
geda-user mailing list
geda-user@moria.seul.org
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user

Reply via email to