On Sat, 2010-04-17 at 13:25 +0200, Stefan Salewski wrote: > On Sat, 2010-04-17 at 13:10 +0200, Stefan Salewski wrote: > > On Sat, 2010-04-17 at 12:37 +0200, Stefan Salewski wrote: > > > > > > > > I think I have to rename all of them, including John Luciani's. > > > > > > > > > > You have components in your schematic named Rf and Cf without numbers. > > These seems to have no connection in the netlist. > > The missing number in refdes seems to be a problem. > > > > > > OK, seems to be all fixed now, see > > http://www.ssalewski.de/tmp/armin20100417.tar > > > refdes without a digit at the end of the name seems to be indeed a big > problem, I am not sure if this is stated at a prominent location in the > gEDA/PCB documentation?
Specifically, it is the _lower case_ letter at the end which is ignored. It was a (mis)feature designed to support "IC1a" "IC1b" as the same part, "IC1" in the netlist. I don't "think" upper case letters at the end of a refdes (without a number) cause a problem. -- Peter Clifton Electrical Engineering Division, Engineering Department, University of Cambridge, 9, JJ Thomson Avenue, Cambridge CB3 0FA Tel: +44 (0)7729 980173 - (No signal in the lab!) Tel: +44 (0)1223 748328 - (Shared lab phone, ask for me) _______________________________________________ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user