2011/4/5 Abhijit Kshirsagar <abhijit...@gmail.com>: > I have multi-page schematics with a number of off-page connectors > (realised using the symbols input-1.sym and input-2.sym) as described > in the howto: > [1]http://www.geda.seul.org/wiki/geda:na_howto#what_is_the_net_attribut > e_used_for > I noticed that if multiple net attributes happen to be present on the > same net in the schematic, then the netlist seems to treat them as > completely different nets and /ignores/ any interconnections.
I suspect your case is covered by one of the bugs below: https://bugs.launchpad.net/geda/+bug/698395 https://bugs.launchpad.net/geda/+bug/698524 https://bugs.launchpad.net/geda/+bug/698570 Two of them were recently fixed in the git HEAD, so you can try to use development version of gnetlist to check. The remaining bug is harder to fix. -- Krzysztof Kościuszkiewicz "Simplicity is the ultimate sophistication" -- Leonardo da Vinci _______________________________________________ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user