Sasha Khapyorsky wrote:
> On 22:30 Wed 07 Jan     , Eli Dorfman wrote:
>> I am working with ConnectX HCA and latest fw versiong 2.6.0.
>> The IS4 switch chip does not support portXmitWait reset.
> 
> But does it report XmitWait counter support in ClassPortInfo? Anyway it
> would be better to implement XmitWait reset in accordance to
> ClassPortInfo. Also would be helpful to test it with "non-working" fw -
> in hope that reset attempt is just ignored there.

I understand that ClassPortInfo specifies whether PortXmitWait is supported.
It does not distinguish between get and set operation.
We have seen that ClassPortInfo to IS4 returns garbage.

I don't see what's the point of testing the utility vs. a non working fw.

Eli
_______________________________________________
general mailing list
[email protected]
http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general

To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general

Reply via email to