fixeria has posted comments on this change. ( 
https://gerrit.osmocom.org/c/osmo-gsm-manuals/+/22867 )

Change subject: TRXD: add documentation for TRXDv2 protocol
......................................................................


Patch Set 6:

(1 comment)

https://gerrit.osmocom.org/c/osmo-gsm-manuals/+/22867/5/common/chapters/trx_if.adoc
File common/chapters/trx_if.adoc:

https://gerrit.osmocom.org/c/osmo-gsm-manuals/+/22867/5/common/chapters/trx_if.adoc@516
PS5, Line 516: RFU: variable bit-length::
Ok, the commit message I referred to does not explain why it becomes variable 
length, sorry. But it mentions that RFU will appear in several places: in 
diagram 'Uplink message structure (batched part)' above RFU takes 4 bits. But 
in 'Downlink PDU structure (batched part)' I forgot to replace VER with RFU - 
will correct soon.

> according to packetdiab above it's one byte

Are you sure you are not referring to an earlier version of this patch? In the 
latest version it's either 1 bit (between VER and TN) or 5 bit (replacing VER 
in the batched part).



--
To view, visit https://gerrit.osmocom.org/c/osmo-gsm-manuals/+/22867
To unsubscribe, or for help writing mail filters, visit 
https://gerrit.osmocom.org/settings

Gerrit-Project: osmo-gsm-manuals
Gerrit-Branch: master
Gerrit-Change-Id: I03b2beeb535848b31fd629ba3cd330b43072c08b
Gerrit-Change-Number: 22867
Gerrit-PatchSet: 6
Gerrit-Owner: fixeria <vyanits...@sysmocom.de>
Gerrit-Reviewer: Jenkins Builder
Gerrit-Reviewer: dexter <pma...@sysmocom.de>
Gerrit-Reviewer: osmith <osm...@sysmocom.de>
Gerrit-CC: laforge <lafo...@osmocom.org>
Gerrit-CC: pespin <pes...@sysmocom.de>
Gerrit-Comment-Date: Wed, 14 Apr 2021 15:32:41 +0000
Gerrit-HasComments: Yes
Gerrit-Has-Labels: No
Comment-In-Reply-To: pespin <pes...@sysmocom.de>
Comment-In-Reply-To: fixeria <vyanits...@sysmocom.de>
Gerrit-MessageType: comment

Reply via email to