adude3141 commented on a change in pull request #15955:
URL: https://github.com/apache/beam/pull/15955#discussion_r759573709



##########
File path: 
sdks/java/io/kinesis/src/main/java/org/apache/beam/sdk/io/kinesis/KinesisIO.java
##########
@@ -884,28 +885,81 @@ public PDone expand(PCollection<byte[]> input) {
           getPartitionKey() == null || (getPartitioner() == null),
           "only one of either withPartitionKey() or withPartitioner() is 
possible");
       checkArgument(getAWSClientsProvider() != null, "withAWSClientsProvider() 
is required");
+      producerConfiguration(); // verify Kinesis producer configuration can be 
build
 
       input.apply(ParDo.of(new KinesisWriterFn(this)));
       return PDone.in(input.getPipeline());
     }
 
-    private static class KinesisWriterFn extends DoFn<byte[], Void> {
+    private KinesisProducerConfiguration producerConfiguration() {
+      Properties props = getProducerProperties();
+      if (props == null) {
+        props = new Properties();
+      }
+      return KinesisProducerConfiguration.fromProperties(props);
+    }
 
+    private static class KinesisWriterFn extends DoFn<byte[], Void> {
       private static final int MAX_NUM_FAILURES = 10;
+      /** Usage count of static, shared Kinesis producer. */
+      private static final AtomicInteger producerRefCount = new 
AtomicInteger();
+
+      /** Static, shared Kinesis producer. */
+      private static IKinesisProducer producer;
 
       private final KinesisIO.Write spec;
-      private static transient IKinesisProducer producer;
+
       private transient KinesisPartitioner partitioner;
       private transient LinkedBlockingDeque<KinesisWriteException> failures;
       private transient List<Future<UserRecordResult>> putFutures;
 
       KinesisWriterFn(KinesisIO.Write spec) {
         this.spec = spec;
-        initKinesisProducer();
+      }
+
+      /**
+       * Initialize statically shared Kinesis producer if required and count 
usage.
+       *
+       * <p>NOTE: If there is, for whatever reasons, another instance of a 
{@link KinesisWriterFn}
+       * with different producer properties or even a different implementation 
of {@link
+       * AWSClientsProvider}, these changes will be silently discarded in 
favor of an existing
+       * producer instance.
+       */
+      @SuppressFBWarnings("JLM_JSR166_UTILCONCURRENT_MONITORENTER")
+      private void setupSharedProducer() {
+        synchronized (producerRefCount) {
+          if (producer == null) {
+            producer =
+                
spec.getAWSClientsProvider().createKinesisProducer(spec.producerConfiguration());
+            producerRefCount.set(0);
+          }
+        }
+        producerRefCount.incrementAndGet();

Review comment:
       Sorry for being unclear. I am more concerned about the 'publishing' of 
inconsistent state after releasing the lock/synchronized block in line 936, 
i.e. after crossing the memory fence. producerRecCount is 0, where it should be 
1.
   
   I d say an easy fix could be to simply pull that 
producerRefCount.incrementAndGet() (line 937) into the synchronised block. As 
we aquire the lock/synchronize anyway, this will not hurt. Of course, we could 
consider switching to plain int then as a counter, as it is accessed in 
teardown also behind the lock.
   
   Does this make more sense?
   
   Note: If we were to implement a RefCountingObject here supporting 
retain/release without locking/synchronization the matter would change. This 
would probably need more thoughts though, as this 'static reference' would 
simply move and we still need that kind of lazy initialised singleton instance 
which needs config for initialisation.




-- 