On 12/15/09 11:03 PM, Reza Salari wrote:
Thanks for your response.
While I will try that (although it seems it needs quite amount of
scripting), I remember in the past some people in the mailing list
mentioned problems while using nonbond_params directvie with OPLS-AA and
in response it was generally suggested to avoid doing this kind of
mixing. Like Dr Abraham suggestion here:
http://www.mail-archive.com/gmx-users@gromacs.org/msg23147.html
Have you tried this kind of mixing for OPLS successfully, without being
overridden by the default rules?
The main thing that I am still unsure about is how the previously
mentioned paper converted the sigma values for different combination
rules. It seems that there must be a relatively direct way to do this
without going through the re-parametrization process.
Unfortunately the combination rules are part of the parameterization,
simply because changing the combination rules means changing the
parameters. Hence I would suggest you look for ion parameters that are
compatible with your force field of choice, alternatively a force field
that is compatible with your ions of choice. Since these ion parameters
were developed by Tom Cheatham I presume that Amber would be a suitable
force field.
Regards,
Reza Salari
------------------------------------------------------------------------
*From:* Andrew Paluch <apal...@nd.edu>
*To:* Discussion list for GROMACS users <gmx-users@gromacs.org>
*Sent:* Tue, December 15, 2009 4:34:18 PM
*Subject:* Re: [gmx-users] New ion parameters and OPLS-AA
Read the manual. You can explicitly declare all of your cross terms
rather than using the same mixing rule for all terms. You can easily
write a script to modify your input files accordingly,
Andrew
On Tue, Dec 15, 2009 at 4:06 PM, Reza Salari <resa...@yahoo.com
<mailto:resa...@yahoo.com>> wrote:
Hi All,
Recently there has been a new set of ion parameters published by
Joung and Chetham and I am interested in running some test runs
using these parameters. These set of parameters are based on using
LB rule (arithmetic mean) for sigmas.
However I am using OPLS-AA ff so I am using the combination rule 3
(geometric mean of corresponding A and B values). My question is
that can I use the exact sigma values from Cheatham for my
simulations? I'm almost positive that I have to change these sigma
values to be consistent with the combination rule that I am using.
In fact there is a paper by Horinek et al that has a nice table of
different ionic sigma and epsilon values from different parameter
sets (Aqvist, Jensen, Cheatham,..). The article is here:
http://scitation.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JCPSA6000130000012124507000001&idtype=cvips&gifs=Yes
<http://scitation.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JCPSA6000130000012124507000001&idtype=cvips&gifs=Yes>
In that table, they have mentioned two sigmas; a usual sigma (which
is used with rule 2) and a sigma prime (which can be used with rule
3). However it seems sort of unclear to me how they got these value
since in some references that they've mentioned I could find either
sigma or sigma prime, not both. So I am guessing there must be some
way to convert these two sigmas to each other.
So does anyone know if there is such way? Does GROMACS internally
treats sigmas as "sigma prime" for OPLS-AA? I looked at the manual
and also searched the mailing list to find an explanation but
without luck. I really appreciate any help on clarifying this.
Regards,
Reza Salari
--
gmx-users mailing list gmx-users@gromacs.org
<mailto:gmx-users@gromacs.org>
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before
posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to gmx-users-requ...@gromacs.org
<mailto:gmx-users-requ...@gromacs.org>.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php
--
David van der Spoel, Ph.D., Professor of Biology
Molec. Biophys. group, Dept. of Cell & Molec. Biol., Uppsala University.
Box 596, 75124 Uppsala, Sweden. Phone: +46184714205. Fax: +4618511755.
sp...@xray.bmc.uu.se sp...@gromacs.org http://folding.bmc.uu.se
--
gmx-users mailing list gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php