On 5/8/12 4:08 PM, dina dusti wrote:
Dear Justin,
Thank you very much from your help.
Yes, the micelle was created after 100 ns from start of simulation.
If the first procedure is true, so why the error estimate is so small and why
the error estimate of Rg is so different with Rg(x,y,z)?
For the algorithmic specifics of how the error estimate is calculated, refer to
Berk's paper.
The error estimate is smaller in the case of starting after 100 ns because in
the case where you consider all the data, you are calculating Rg of diffuse
molecules and a micelle. You're considering two different states and thus your
data are poorly converged with respect to that measurement.
-Justin
--
========================================
Justin A. Lemkul
Ph.D. Candidate
ICTAS Doctoral Scholar
MILES-IGERT Trainee
Department of Biochemistry
Virginia Tech
Blacksburg, VA
jalemkul[at]vt.edu | (540) 231-9080
http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin
========================================
--
gmx-users mailing list gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to gmx-users-requ...@gromacs.org.