Dear All:

I encountered a problem when doing umbrella sampling. The distance calculated 
by grompp and g_dist is different, as shown by the following:

grompp  z component of g_dist(since I am constraining the distance between two 
groups along the z direction, I should calculate the z component of the 
distance, right?)
2.986   2.96
2.953   2.95
2.931   2.92
2.936   2.9355
2.844   2.83

There is an obvious difference between the distance calculated by the grompp 
and the g_dist, I also found that some post similar problems in the maillist, 
but I didn't found answers for the following questions.
(1)Why there is a such difference? 
(2)Also, does anyone know which value is used in the umbrella sampling 
simulations, the grompp result or the g_dist result?
(3)how to choose the right starting conformations since there is such a 
difference? 

I also pasted the pull code I used as follows:

pull    =       umbrella
pull_geometry   =       direction
pull_dim        =       N N Y
pull_start      =       yes
pull_nstxout    =       500
pull_nstfout    =       500
pull_ngroups    = 1
pull_group0             =       Protein
pull_group1             =       AMA
pull_init1              =       0 
pull_rate1              =       0.000;nm/ps
pull_k1         =       4500 ;kJ/mol/nm^2


Thanks in advance!!

Best regards,
Ruo-Xu Gu
-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
* Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to