How can I find out about the options being executed
while accessing CPRS? As far as the OR CPRS GUI CHART option is concerned, it
does not have an ENTRY ACTION defined in the OPTION file.
Thanks
Usha
----- Original Message -----
Sent: Wednesday, October 26, 2005 7:09
PM
Subject: Re: [Hardhats-members] NOLINE
error while accessing CPRS
My second guess on the LOOP+6^XQOR1 problem is that you have a OPTION
being executed somehow that has an ENTRY ACTION that has a line^routine
reference that is invalid.
Your mail problem most likely is that a message is trying to be sent to a
remote domain that is open and should not be.
On 10/26/05, Usha
<[EMAIL PROTECTED]> wrote:
After rebuilding all the primary and secondary
menu options, the following is the output of D ^XTER
EHR>D ^XTER In
response to the DATE prompt you can enter: 'S'
to specify text to be matched in error or routine
name 6 errors logged on 10/26/2005 6)
<READ>L3+1^XMC1A
10:44:44 EHR,EHR 2028
|TCP|2078 5)
<NOLINE>LOOP+6^XQOR1
10:44:05 EHR,EHR 2560
//./nul:2560 4)
<READ>L3+1^XMC1A
10:42:54 EHR,EHR 2028 |TCP|2078
3)
<READ>L3+1^XMC1A
10:41:03 EHR,EHR 2028
|TCP|2078 2)
<NOLINE>LOOP+6^XQOR1
10:40:35 EHR,EHR 2556
//./nul:2556 1)
<READ>L3+1^XMC1A
10:39:14 EHR,EHR 2028 |TCP|2078
Make sure YOUR emails don't get lost! Download Mailinfo here
|
- Re: [Hardhats-members] NOLINE error while accessing CPRS Usha
-