Hi All,

Does anyone have any experience in defining a Cascaded CISCO Ficon switch 
in HCD?

I believe that we need to know both the Domain ID of the Switch and the 
Switch Address, but we are unable to determine what the Switch address is? 
Documentation on the Internet (an IBM redbook!) states that Switch Address 
should be the Hex version of Domain ID, but then goes on to show that both 
numbers are the same e.g x'21' and 21. A D M=DEV(A000) of our devices 
shows the following:

CHP                   24   26
ENTRY LINK ADDRESS    4182 43A2
DEST LINK ADDRESS     6608 6808
PATH ONLINE           Y    N
CHP PHYSICALLY ONLINE Y    Y
PATH OPERATIONAL      Y    Y
PATHS NOT VALIDATED

The entry link address's shown are not what we have coded in HCD? Do I need 
to simply change the entry link address to 41 and 43 (from 66 and 68 as the 
redbook implied!) ?

Any help appreciated from anyone whose coded this before....

Phil Kingston.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to