On Wed, 2 Sep 2009 09:44:21 +0300, גדי &#1489;ן אבי <[email protected]> wrote:
>Hi, > >A few months ago we replaced our Sysplex Timer (9037-002) with STP. > >We have two z890s. Each z890 has a production LPAR and a test LPAR. The production LPARs form one basic sysplex, and the test LPARs form another sysplex. > >All LPARs are running z/OS 1.9. > >The CLOCKxx members look like this: >OPERATOR NOPROMPT >TIMEZONE E.00.00.00 >ETRMODE NO >ETRZONE NO >STPMODE YES >STPZONE YES >ETRDELTA 1 > >At the end of September (on the 27th) we will change back to winter time. > >In the past, when we had a sysplex timer, we would shut down all systems, change the time on the sysplex timer, wait an hour and IPL the systems to change the time. > >What would be the suggested procedure today when using STP? > >TIA > >Gadi > In the Timing Network tab of the Sysplex Time task, look at the "Adjust TimeZone" panel and you'll see a method for adding/subtracting DST offset. See the Redbook for gory details, including screenshots, etc. SG24-7281-01 STP Impl Guide. p175-177 cheers Peter ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html