Everyone might be interested to know that there are some IMS datasets (I forget 
which) that *cannot* be PDSE.  They must be PDS.  Trust me, I tried them as 
PDSE and spend a long time trying to figure out why I couldn't get things 
working!  :-)  So to make life easy on yourselves if you have IMS I wouldn't 
even think about converting any to PDSE.  (I think it was the ACBLIB, and maybe 
also the DBDLIB and PSBLIB.  Probably the actual load libs are OK, but why 
chance it?)

On 9/11/2009 at 10:17 AM, in message
<listserv%[email protected]>, Mark Zelden
<[email protected]> wrote:
> On Fri, 11 Sep 2009 09:01:02 -0700, Edward Jaffe
> <[email protected]> wrote:
> 
> 
>>In our shop we use SMS to assign default data classes that specify "Data
>>Set Name Type  . . . . . : LIBRARY". So, if you think you're allocating
>>a PDS in batch, it's really a PDSE unless you specify DSNTYPE=PDS to
>>explicitly override this behavior.
>>
> 
> One of our small monoplex LPARs (absorbed via consolidation) has their
> default set to DSNTYPE(LIBRARY) in IGDSMSxx.    This applies to everything,
> SMS assigned or not.  So even ISPF data sets that are not recommended
> to be PDSE are (but I've never seen a problem because of it).
> 
> Mark
> --
> Mark Zelden
> Sr. Software and Systems Architect - z/OS Team Lead
> Zurich North America / Farmers Insurance Group - ZFUS G-ITO
> mailto:[email protected] 
> z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/ 
> Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html 
>  
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html 



>>> 

The information contained in this electronic communication and any document 
attached hereto or transmitted herewith is confidential and intended for the 
exclusive use of the individual or entity named above.  If the reader of this 
message is not the intended recipient or the employee or agent responsible for 
delivering it to the intended recipient, you are hereby notified that any 
examination, use, dissemination, distribution or copying of this communication 
or any part thereof is strictly prohibited.  If you have received this 
communication in error, please immediately notify the sender by reply e-mail 
and destroy this communication.  Thank you.

-- 

Frank Swarbrick
Applications Architect - Mainframe Applications Development
FirstBank Data Corporation - Lakewood, CO  USA
P: 303-235-1403

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html