I had that originally, the job asked me to over write TZ11P1, so I terminated. Didn't want to write over the ipl text on the volser with no maint.
*05 ICK21836D IPL TEXT EXISTS ON TZ11P1. REPLY U TO OVERLAY, ELSE T So you are saying to setup like this, that will over write the TZ11P1 volser. //STEP001 EXEC PGM=ICKDSF, // REGION=2M //SYSPRINT DD SYSOUT=* //IPLDD DD DSN=SYS1.SAMPLIB(IEAIPL00), // DISP=SHR,UNIT=SYSDA,VOL=SER=TZ11A1 //IPLVOL DD DISP=OLD, // UNIT=3390, // VOL=SER=TZ11P1 //SYSIN DD * REFORMAT DDNAME(IPLVOL) - VERIFY(IPLVOL) - IPLDD(IPLDD,OBJFORMAT) NOBOOTSTRAP /* -----Original Message----- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of McKown, John Sent: Thursday, September 09, 2010 4:03 PM To: IBM-MAIN@bama.ua.edu Subject: Re: Disable Wait After Maintenance > -----Original Message----- > From: IBM Mainframe Discussion List > [mailto:ibm-m...@bama.ua.edu] On Behalf Of Dazzo, Matt > Sent: Thursday, September 09, 2010 2:57 PM > To: IBM-MAIN@bama.ua.edu > Subject: Re: Disable Wait After Maintenance > > John, thanks for the sample. My jcl used is below, I got > cc=12. Volser=TZ11A1 is the volser with the maint, my current > running res volume is TZ11P1 without maint. Is this jcl correct? tks > > //STEP001 EXEC PGM=ICKDSF, > // REGION=2M > //SYSPRINT DD SYSOUT=* > //IPLDD DD DSN=SYS1.SAMPLIB(IEAIPL00), > // DISP=SHR,UNIT=SYSDA,VOL=SER=TZ11A1 > //IPLVOL DD DISP=OLD, > // UNIT=3390, > // VOL=SER=TZ11A1 > //SYSIN DD * > REFORMAT DDNAME(IPLVOL) - > VERIFY(IPLVOL) - > IPLDD(IPLDD,OBJFORMAT) NOBOOTSTRAP > /* > > > ICKDSF - MVS/ESA DEVICE SUPPORT FACILITIES 17.0 > > REFORMAT DDNAME(IPLVOL) - > VERIFY(IPLVOL) - > IPLDD(IPLDD,OBJFORMAT) NOBOOTSTRAP > ICK00700I DEVICE INFORMATION FOR 340B IS CURRENTLY AS FOLLOWS: > PHYSICAL DEVICE = 3390 > STORAGE CONTROLLER = 2105 > STORAGE CONTROL DESCRIPTOR = E8 > DEVICE DESCRIPTOR = 0C > ADDITIONAL DEVICE INFORMATION = 48000035 > TRKS/CYL = 15, # PRIMARY CYLS = 10017 > ICK04000I DEVICE IS IN SIMPLEX STATE > ICK03091I EXISTING VOLUME SERIAL READ = TZ11A1 > ICK31300I VERIFICATION FAILED: VOLUME-SERIAL WRONG. > ICK30003I FUNCTION TERMINATED. CONDITION CODE IS 12 > 15:47:39 09/09/10 > You kept the constant IPLVOL in the VERIFY. You need to replace that with the actual volser of TZ11P1. C 'IPLVOL' 'TZ11P1' ALL WORD and try again. -- John McKown Systems Engineer IV IT Administrative Services Group HealthMarkets(r) 9151 Boulevard 26 * N. Richland Hills * TX 76010 (817) 255-3225 phone * (817)-691-6183 cell john.mck...@healthmarkets.com * www.HealthMarkets.com Confidentiality Notice: This e-mail message may contain confidential or proprietary information. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. HealthMarkets(r) is the brand name for products underwritten and issued by the insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake Life Insurance Company(r), Mid-West National Life Insurance Company of TennesseeSM and The MEGA Life and Health Insurance Company.SM ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html