Did you re-write the IPLTEXT from SYS1.SAMPLIB on the target volume?

Waitstate 75 rsn 06 says, The IPL text on the volume used to IPL did not match 
the nucleus code resident on that volume.

Mark Jacobs


-----Original Message-----
From: IBM Mainframe Discussion List on behalf of Dazzo, Matt
Sent: Thu 9/9/2010 3:16 PM
To: IBM-MAIN@bama.ua.edu
Subject: Disable Wait After Maintenance
 
I installed z1.11 and it's up and running in our sand box with no problems. 
There were approximately 310 PTF's that were in the smpe zones not applied, so 
I ran an smpe apply with no issues to an alternate set of res volumes. When 
attempting to ipl from the alternate res volume I get a disabled wait psw 
000A000000600075 and 000A000000900074. I have read the process of determining 
the reason code from the MVS codes book but 'no comprehend'. What is the 
easiest way to determine why I'm getting this psw? Thanks Matt


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,