> -----Original Message----- > From: IBM Mainframe Discussion List > [mailto:[EMAIL PROTECTED] On Behalf Of Len Rugen > Sent: Friday, November 11, 2005 1:05 PM > To: IBM-MAIN@BAMA.UA.EDU > Subject: Quick HMC console question > > > Ok, Friday play day question. > > I decided to dust off my sandbox LPAR to test a new version > of ThruPut Manger. This LPAR hasn't been running in awhile, > so when I get to the datacenter, I find the 3274 controller > has died. I decide to use the HMC console to get things > going, but I'm stuck. > > I have a parm error in JES2, I get the WTOR line saying that > I need to fix it, but NOT the lines in error. Is there some > way to route MORE messages to the HMC Operating System Messages area? > > This is a z800, I guess I wish it were a z880 in this case.... > > Thanks > > > Len Rugen
V CN(*),ACTIVATE V CN(*),ROUT=ALL S JES2,PARM=(WARM,NOREQ) -- John McKown Senior Systems Programmer UICI Insurance Center Information Technology This message (including any attachments) contains confidential information intended for a specific individual and purpose, and its' content is protected by law. If you are not the intended recipient, you should delete this message and are hereby notified that any disclosure, copying, or distribution of this transmission, or taking any action based on it, is strictly prohibited. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html