On Wed, Dec 15, 2010 at 11:22 AM, Lorne Dudley <dudl...@queensu.ca> wrote: <snip>
> > ----------------------------------------------------------------------------- > TITLE 'CVTUSER TEST' > CVT DSECT=YES,LIST=YES .CVT DSECT > Y CSECT , > * > * REGISTER EQUATES > * > R0 EQU 0 . > R1 EQU 1 . > R2 EQU 2 .CVT ADDRESS > R3 EQU 3 .CVTUSER ADDRESS > R4 EQU 4 . > R9 EQU 9 .BASE ADDRESS OF THIS EXIT > R10 EQU 10 . > R15 EQU 15 . > * > SAVE (14,12),,X_V1.0_&SYSDATE SAVE & ID > LR R9,R15 .SET UP ADDRESSABILITY > USING Y,R9 .SET UP ADDRESSABILITY > USING CVT,R2 .CVT DSECT > <unsnip> * > MODESET KEY=ZERO,MODE=SUP > * > R2 is set incorrectly. It needs to be loaded as follows: using PSA,R0 include macro: IHAPSA L R2,FLCCVT r2 = address of CVT drop r0 --> Delete or comment out this line L R2,CVTPTR LOAD UP CVT ADDRESS L R3,CVTUSER LOAD CVTUSER ADDRESS > * move 4 characters to CVTUSER > MVC R3(4),=C'TEST' > RETURN (14,12),RC=0 .RETURN TO CALLER > LTORG > PATCH DC 2D'0' .16 BYTE PATCH AREA > END > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO > Search the archives at http://bama.ua.edu/archives/ibm-main.html > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html