You call routine IEFYS . See SYS1.SAMPLIB(SMFEXITS) for examples on how to 
use it. 

.
.
JO.Skip Robinson
SCE Infrastructure Technology Services
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[email protected]



From:   John McKown <[email protected]>
To:     [email protected]
Date:   07/25/2011 08:13 PM
Subject:        Re: RESEND - RE: Write directly to the JESLOG for a job
Sent by:        IBM Mainframe Discussion List <[email protected]>



Perhaps it was JESMSG and not JESLOG. It was a long time ago. What is
the JESMSG interface called?

On Mon, 2011-07-25 at 17:10 -0700, Skip Robinson wrote:
> I know that John specifically asked about writing to JESLOG. If it would 

> satisfy his requirement to write into the JESMSG file, there is a 
> standard, documented interface for writing messages there. No 
possibility 
> of going to syslog regardless of system settings. 
> 
> .
> .
> JO.Skip Robinson
> SCE Infrastructure Technology Services
> Electric Dragon Team Paddler 
> SHARE MVS Program Co-Manager
> 626-302-7535 Office
> 323-715-0595 Mobile
> [email protected]
> 
> 
> 
> From:   Jim Thomas <[email protected]>
> To:     [email protected]
> Date:   07/25/2011 04:59 PM
> Subject:        RESEND - RE: Write directly to the JESLOG for a job
> Sent by:        IBM Mainframe Discussion List <[email protected]>
> 
> 
> 
> Sir,
> 
> Just thought of something ... (will look at the manuals tomorrow, 
> to confirm) .. I seem to remember a difference in behavior (if 
> you're using ROUTCDE=11) between LINKAGE=SVC (default) and 
> LINKAGE=BRANCH. IIRC, LINKAGE=BRANCH will not allow the message
> to be sent to SYSMSG .... or do I have that mixed up ?? .. 
> 
> Please note that there are limitations in doing this. 
> 
> Further, is a SYSOUT DD coded when you use the ROUTECDE=11 ?. 
> 
> Kind Regards
> 
> Jim Thomas
> 617-233-4130             (mobile)
> 636-294-1014                (res)
> [email protected] (Email)
> 
> 
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On 
> Behalf
> Of McKown, John
> Sent: Monday, July 25, 2011 4:10 PM
> To: [email protected]
> Subject: Write directly to the JESLOG for a job
> 
> I vaguely remember at one time seeing some code which did "chain 
chasing" 
> to
> find the ACB for the JESLOG SPOOL dataset. The code could then do a PUT 
> with
> an ACB= and RPL= to write to the JESLOG like a VSAM ESDS file. This 
> avoided
> any chance of going to the SYSLOG like sometimes happens with WTO
> ROUTCDE=11. Does anybody else remember this or have the code?
> 
> John McKown
> Systems Engineer IV
> IT
> 
> Administrative Services Group
> 
> HealthMarkets(r)
> 
> 9151 Boulevard 26 * N. Richland Hills * TX 76010
> (817) 255-3225 phone *
> [email protected] * www.HealthMarkets.com



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to