Hi, now speaking as a DB2 sysprog.
Today the mvs group issued the PD REPLACE,PAGE=(sys1.page01,sys1.page04) command which ends successfully. However seconds later we got several abends in DB2 V8 dealing with RC00C90101, seconds later several abends S02A RSN8 and then several STC fails with different kind of abends mostly S0C4. This includes CICS, TCPIP and third party software and also the CATALOG asid. Environment z/OS R4. The logrec shows four abends for RC00C90101 followed by hundreds of S02A RC8. Because of huge number of dumps written by CICS among other we had to cancel CICS and other STC. After restart of DB2 some VSAM datasets gets IDC-Errors. We're able to delete those VSAM cluster and start DB2 recover. We`ve been able to delete those datasets from a different LPAR sharing the data. I was wondering why so I issue a F CATALOG,RESTART and after this all VSAM cluster looks fine. But still VTAM dumps several S0C1 abends so we end up in an IPL later. During the PD REPLACE we had about 14 active pagedatasets on this image. So you see we are storage constraint at this time because of end of year activities. I know it's just feeling but could the PD REPLACE cause the problems we've seen? Not sure if the mvs group will open a PMR. Roland ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html