There is probably PIN'd data in the cache.  I've seen this with DS8000s and it 
required intervention by a CE to resolve this.

----------------------------------------------------------

I should have mentioned that did re-assign 8 volumes from LCU-01 to LCU-03 and 
it went without any errors. Decided to RUN Stand Alone DSF to initialize a 
volume and below is what I get. 

Equipment Check on 2xx

CSW: 103ED8 02000020
CCW: 041108A58 20000020

ICK10710I - I/O Error Occurred on Device 280

ICK31024 - Unable to open Volume


I have both Storage Manger along wth DSCLI connected to the DS6800.

Thanks 
Sonny Gupta

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html