Something like : LG GR0,CURR_STCK UTC ALG GR0,LPAR_STCK_OFFSET Local time STCK offset as signed value 64-bit STG GR0,NEW_STCK New STCK value STCKCONV STCKVAL=NEW_STCK, CONVVAL=.....etc etc
Obviously this assumes you know the UTC offset at the time of the LPAR Rob Scott Lead Developer Rocket Software 275 Grove Street * Newton, MA 02466-2272 * USA Tel: +1.781.684.2305 Email: rsc...@rs.com Web: www.rocketsoftware.com -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Charles Mills Sent: 28 February 2012 18:39 To: IBM-MAIN@bama.ua.edu Subject: Re: How convert "historic" STCK to local time? If I had a TOD clock value from roughly six months ago, how would I use STCKCONV to convert it to local time for the LPAR's locale? Charles -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Rob Scott Sent: Tuesday, February 28, 2012 10:12 AM To: IBM-MAIN@bama.ua.edu Subject: Re: How convert "historic" STCK to local time? STCKCONV and CONVTOD are both provided macro services to translate between STCK values and various date/time formats ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN