We have a problem with abend SEFF in a batch job.
We are looking for it in all places (IBM-MAIN, ibm.com, google, IBM
Manuals z/os 1.6 ....) and we don't have find something.
The abend step is about a access program to IDMS database in retrieval (NO
update mode).
We can't understand why we can't find this system code in anywhere.

We paste the abend below:

02.12.10 JOB70013  IEA995I SYMPTOM DUMP OUTPUT  754
754             SYSTEM COMPLETION CODE=EFF
754              TIME=02.12.05  SEQ=00921  CPU=0000  ASID=0041
754              PSW AT TIME OF ERROR  078D2000   8005EA42  ILC 2  INTC FF
754                ACTIVE LOAD MODULE      ADDRESS=00058310  OFFSET=0000
754                NAME=RHDCOMVS
754                DATA AT PSW  0005EA3C - 00000000  0AFF07F4  E2C5C3E4
754                GR 0: 00000001   1: 00088008
754                   2: 000714DC   3: 00000007
754                   4: 8005EB34   5: 0005EA40
754                   6: 0005EA10   7: 00070728
754                   8: 00088008   9: 00070E20
754                   A: 00068050   B: 0005D1C8
754                   C: 0005EA4C   D: 000716E4
754                   E: 0005DA08   F: C3C4D4E2
754              END OF SYMPTOM DUMP
02.12.10 JOB70013  IEF450I R0170396 PASO030 - ABEND=SEFF U0000
REASON=00000000


Thank's a lot

Jorge García Juanino
PRODUCCIÓN/TÉCNICA SISTEMAS HOST
MAPFRE Informática A.I.E
TELF: 91 - 581.27.34
MAILTO:[EMAIL PROTECTED]

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to