On Fri, 11 Jun 2004 09:18:54 +0100, Perryman, Brian <[EMAIL PROTECTED]> 
wrote:

>Hi folks
>
>Hopefully Mike Wood will jump in here..
>
>Is it possible to get RMM to specify what volume is used when a scratch 
tape is requested? We have a virtual tape device (BusTech's 'Mainframe 
Appliance for Storage'). It pretends to be a bank of sixteen 3490 tape 
drives. When a tape mount for a scratch volume is requested, this device 
intercepts the 'PRIVAT' message and picks a volume which it thinks is a 
scratch volume, and mounts it.
>
>This gives me a problem in that I have to keep the MAS scratch list in 
step with what RMM thinks are scratch (or more importantly, NOT scratch). 
There is a BusTech utility batch program to do this, running off an RMM 
scratch report. For
>each tape in the RMM scratch list, it tells the MAS to scratch the volume. 
This is working ok most of the time.
>
>However there is a slight window of risk. If between the time the report 
was generated and the time the scratch requests go in, a scratch tape is 
used to satisfy a mount request, it can get scratched inside the MAS even 
though the tape is now in use. RMM of course won't know about this.
>

Brian,

I found this thread in the archives, we are looking at the BusTech MAS 
device at the moment. You know the device by now, I saw in a later thread 
that you were satisfied by the box. Are you still?

I am interested in the potential window of risk you mentioned. Did you 
expirience any problems with this and if so, how did you deal with them?

Thanks,
Kees.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to