In a recent note, Tom Marchant said:

> Date:         Fri, 7 Jul 2006 08:08:29 -0500
> >
> >    //STEP     EXEC  PGM=IEBGENER
> >    //ALLOC     DD   DISP=(MOD,DELETE),UNIT=&DASD,DSN=...,SPACE=...
> >    //SYSUT2    DD   DISP=OLD,DSN=*.ALLOC,UNIT=&DASD
> >
> >...?  I believe the ALLOC data set is uncatalogued before SYSUT2 is
> >catalogued (order of DD statements?).  Of course this requires an
> >elegible storage volume in addition to the one used by the ALLOC DD.
> >
> I don't think so.  In an SMS environment I believe the data set is
> cataloged when it is created.  Even if not, you run the risk of
> trying to allocate it on the same volume.
> 
Experiment shows you're correct.  It fails except for a non-SMS
managed HLQ.  I hadn't realized SMS introduced such a restriction.

I'm not much concerned about having only a single eligible
storage volume.

-- gil
-- 
StorageTek
INFORMATION made POWERFUL

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO