On Tue, 13 Mar 2007 16:21:20 -0400, Collinson.Shannon
<[EMAIL PROTECTED]> wrote:

>I need to create a usermod to handle a non-IBM product zap to an LE
>module that I do NOT want hitting the actual production LE module.
>Instead, I want to be able to copy the module (or use some other SMP/e
>controlled method) from the current CEE.SCEELPA library into a
>product-specific library and apply the zap.  If any maintenance comes in
>for the LE module (CEEPLPKA), I want the usermod to get regressed, so
>we'll know the product-specific copy needs to get updated.  This is for
>a date-simulation product, which apparently is handling the ability to
>override LE-calls to date routines in much the same way as any other
>date-simulation product, so I'm hoping that someone else has hit the
>same requirement in the past.  
>

Just use UCLIN to update the UMID of the module. If some maintenance
hits it, you will get the SMP/E error message that the sysmod does
not pre or sup usermod nnnnnnn.

Example:

SET    BDY(tgt).               
UCLIN .                            
ADD MOD(CEEPLPKA)   UMID(UMCEE01).  
ENDUCL.


Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group:  G-ITO
mailto:[EMAIL PROTECTED]
z/OS and OS390 expert at http://searchDataCenter.com/ateExperts/
Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to