On Wed, 4 Apr 2007 13:39:05 -0500, Patrick Lyon <[EMAIL PROTECTED]> wrote:

>On Wed, 4 Apr 2007 12:40:36 -0500, Thomas Raskin
><[EMAIL PROTECTED]> wrote:
>
>>Am interested in knowing if most people still IPL for time change - spring and
>>fall - and if anyone does not, how they handle this.
>>
>>Thanks, Tom
>>
>
>
>I would like to take this question one step further - for any shop that
does not
>IPL and leave the system down for an hour in the fall, do they have IMS in
>their shop?  It is still my understanding that IMS has to be shut down for that
>hour falling back.  Is this correct?
>

Not since before IMS V6 (assuming you *don't* run GMT=LOCAL).   But that 
doesn't mean you don't have applications that store the local time (instead of 
GMT) in logs or tables.  In that case, you still have to shut down for an hour.

Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group:  G-ITO
mailto:[EMAIL PROTECTED]
z/OS and OS390 expert at http://searchDataCenter.com/ateExperts/
Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------