Allan,
   
  I tried your suggestion (shuttdown the STC ) & retried the recycle and it 
worked.  Thanks.

"Staller, Allan" <[EMAIL PROTECTED]> wrote:
  
DFHSM was attempting to recycle the tape. Several messages were
displayed "ARC0440I - VOLUME 032009 CONTAINS AN INVALID CDD OR A TAPE
POSITIONING ERROR HAS OCCURRED. ARC0734I ACTION=RECYCLE FRVOL=032009
TOVOL=****** BLOCKS= 1 RC= 68, REASON=
DSN=HSM.HMIG.V143501.Y321.OMMD0$02.J7287"


In my experience there are usually 2 root causes for this.
1) The tape has been partially written over.
2) IO error on tape.

Corrective actions (in order of preference:

1) Sometimes, HSM does get "confused". Bounce DFHSM and retry.

In case (2) delete the offending file (the one with with the IO error)
and retry. This file is normally the file immediately before the 1st
RC=68. i.e. 
Single file delete and recovery.

In case (1) an HSM audit to identify the possible datasets and update
the CDS. In an extreme case, DELVOL PURGE will be required. This will
clean up the CDS of all files that HSM thinks are on that volume.