Mauri Kanter wrote:
Hi list:

We are issuing the command
MN JOBNAMES,T
from our COMMNDxx

In addition our CONSOLxx member contains
MONITOR(JOBNAMES-T) for each defined console

Now, there are cases on which we want to IPL our DR site (a shadow image copy of the first, using a different CPC) without any of the actual hardware consoles defined on our CONSOLxx, but just with the HMC console. The system IPLs ok but the messages IEF403I and IEF404I do not appear ... After the system is up, if we open a VTAM SMCS console the messages appear, and if we close the just opened SMCS console again the IEF403I and IEF404I stop to appear. Long history short, looks that we need at least one target console active in order to receive the IEF403I and IEF404I messages.
We do need the IEF403I and IEF404I messages for our IPL automation rules.

Any idea how to force the system to issue the IEF403I and IEF404I messages when only the HMC console is available ?

Thanks in advance.

Mauri.

The MONITOR command is not supported in COMMNDxx any more.
Use COM='SETCON MN,JOBNAMES=(ON,LOG),T=ON' instead.

See MVS Console Commands

http://publibz.boulder.ibm.com/epubs/pdf/iea2g181.pdf


--
Richard

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html