In <8568cbf65a535f4ab31b5b299337720a0199f...@nltnzmdowx053.dow.com>, on
01/08/2009
   at 08:21 AM, "Tidy, David (D)" <dt...@dow.com> said:

>Thanks for the reply. These are newly initialised empty volumes. We do
>the logical copy because we up-sequence the volume id, and build a new
>catalog (with the volume id in the name) as we go.

The obvious thing to do is to use indirect cataloging and to keep VSAM off
of the residence volumes. That requires, of course, a naming convention
that ties off-res target libraries to the right residence volume set.
 
-- 
     Shmuel (Seymour J.) Metz, SysProg and JOAT
     ISO position; see <http://patriot.net/~shmuel/resume/brief.html> 
We don't care. We don't have to care, we're Congress.
(S877: The Shut up and Eat Your spam act of 2003)

----------------------------------------------------------------------