Hello,

We are installing a new DASD array with 33 TB of capacity with
approximately 1/3 of the capacity being setup as 3390-3's, 1/3 as 3390-9's
and the last 1/3 as 3390-27's.  I am wondering if anyone has any experience
or documentation that would suggest how many Hyper PAVs per LCU we should
define.  The LCUs will contain an even mix (from a capacity perspective) of
the 3390-3's, 3390-9's and 3390-27's.




Pete Eggebeen