Mark,

The follow on from Sysplex timers is Server Time Protocol. It is
microcode on the processors and uses the HMC. It isn't free however.
Search the Redbook Library (there are 2 volumes, perhaps three) on the
topic. 

Alan

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On
Behalf Of Mark Steely
Sent: Wednesday, March 11, 2009 17:10 
To: IBM-MAIN@bama.ua.edu
Subject: Time Change (Sync)

We are z/OS V1R9 on a z/10 2098-N01 processor. We have 2 CPU's both z/10
2098 - not sysplex. We do have a CTC connection between the two
machines. What would be the best way to have the time automatically be
sync with each other and with GMT. I have heard of sysplex timers , but
I don't think that how it is handled now. Any insight would be helpful. 
 
Thank You


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------