(Re-posting because ???) I can't locate the original post in this saga, which mentioned a lot of 'no applicable FMID' messages. I'm curious how that happened. When we order general (mass) maintenance, RECEIVE FROMNETWORK examines our SMPE environment and looks only for PTFs that are in fact applicable. It ignores fixes that are already RECEIVED and chooses fixes as needed by installed products. There should be very few 'no applicable' messages. The reported problem calls into question OP's ordering process.
Specifically, if specific PTFs are ordered by number, it's up to the customer to vet the list. The only situation I can recall that requires this manual intervention is the rare case where a product cannot be APPLIED because of an error hold on the FMID itself. In that case, RECEIVE FROMNETWORK does not acknowledge the need for maintenance because the FMID is not installed. The fixing PTF must be ordered and installed by name along with the FMID, after which RFN will resume its role. . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-543-6132 Office ⇐=== NEW robin...@sce.com -----Original Message----- From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of Bill Giannelli Sent: Friday, June 12, 2020 4:09 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: (External):Re: SMPe Apply not working CAUTION EXTERNAL EMAIL I really appreciate everyone's help here! The issue I had I believe was that I failed to specify FORFMID. However, I need to take a step back and review my SMPe environment. The CSI was handed off to me and I am finding some things wrong, like missing FMIDs for some of my base products. thank you Bill ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN