I have one that's puzzling me and I'm sure there's a simple solution/answer.  
I'm seeing 2 jobs running on a single system that are hitting an enqueue 
problem on a parmlib.  The JCL in both jobs has DISP=SHR, yet one of the jobs 
has an exclusive ENQ on the library.  Here's the scenario:

Job A is a system backup job.  It does a bit of early processing, then runs an 
FDRFlash of most of our disk, then runs FDR to back up the offline volumes 
created in the flash as well as some volumes that weren't flashed.  Once the 
backup step is done (3 hours later) it does some more post backup processing.  
There are 3 steps in the post processing that allocate this parmlib, all 
allocating the same member - call it A.B.C.PARM(MEMB), all with DISP=SHR.

Job B is a cyclical job that runs in a matter of a few seconds and runs every 5 
minutes.  It also has A.B.C.PARM(MEMB) DISP=SHR as well as A.B.C.PARM(MEMZ) 
DISP=SHR in a different step.  

Timing:

Job A started and was doing its preliminary work.
Job B started and ended successfully.
Job A does the flash step and starts the full volume dumps.
Job B comes along again and can't start because job A has an exclusive ENQ on 
A.B.C.PARM.  Job B does not start until job A has completed the last step with 
A.B.C.PARM in the JCL.  

A couple other points are that A.B.C.PARM is on a volume that was flashed, so 
the source volume wasn't part of the backup.  The job steps in both jobs with 
A.B.C.PARM in them are all conditional steps that actually didn't execute.  

So my question is what could have caused an ENQ change from SHR to OLD when the 
JCL explicitly has SHR?  

TIA,

Rex

The information contained in this message is confidential, protected from 
disclosure and may be legally privileged.  If the reader of this message is not 
the intended recipient or an employee or agent responsible for delivering this 
message to the intended recipient, you are hereby notified that any disclosure, 
distribution, copying, or any action taken or action omitted in reliance on it, 
is strictly prohibited and may be unlawful.  If you have received this 
communication in error, please notify us immediately by replying to this 
message and destroy the material in its entirety, whether in electronic or hard 
copy format.  Thank you.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to