For some reason hadn’t totally  cleared the Parmater list to SVC 122 the flag 
bit indicated a dcb was present when I didn’t have one 

Thanks sorry 

> On Nov 1, 2021, at 12:15 PM, Peter Relson <rel...@us.ibm.com> wrote:
> 
> I don't know in what way LSEARCH=YES would help. 
> 
> It is certainly possible to avoid searching tasklib/steplib/joblib. But 
> the 806-0C abend indicates that you apparently have created an erroneous 
> situation that you should figure out before moving forward.
> 
> If you want just to search LPA + LNKLST (after searching JPQ), then use 
> the DCB parameter and identify the DCB pointed to by CVTLINK. This is 
> special-cased by z/OS.
> 
> Peter Relson
> z/OS Core Technology Design
> 
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN