On Fri, 10 Jun 2022 20:17:40 +0700, Robin Atwood wrote:

>Err, FTP, in both directions. 😊
> 
Using a desktop *client* as a way station between two mainframes:
    BINARY
    QUOTE SITE TYPE E
    QUOTE SITE MODE B

RDWs will be visible on the desktop but properly rendered on PUT
to another mainframe.

There is no way to drive the process from a mainframe client.
It does not work for load modules.

-- 
gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN