HI Graham, Both Lizette and Wayne have correctly indicated that doing a CEDA INSTALL as prior to issuing that command the transaction definition is defined within the CSD but not available to CICS for use.
Additionally it may be worth knowing that INSTALL is not possible via DFHCSDUP. If CICS is started with a WARM or EMERGENCY start the CSD is not used to refresh the resource definitions within CICS, it uses the CICS Global Catalogue instead. If an INITIAL or COLD start is performed it will use the CSD. Doing the INSTALL via CEDA is fine for WARM/EMERGENCY situations but to cater for INITIAL/COLD if a new LIST has been created it is worth checking the GRPLIST parameter in the SIT to ensure that the list is defined to CICS start-up. The SIT can be located by checking the member name in the data set defined via the SYSIN DD statement in the CICS step of the start-up JCL . Kind Regards - Terry Director KMS-IT Limited 228 Abbeydale Road South Dore Sheffield S17 3LA UK Reg : 3767263 Outgoing e-mails have been scanned, but it is the recipients responsibility to ensure their anti-virus software is up to date. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN