Hello I found that UJ08463 PTF was missing which caused this multiple recording of LOGREC.
Applying UJ08463 updates SYS1.NUCLEUS(IECDDDSR), Hold data says that an IPL with CLPA is needed. Instead of an IPL, can I just copy only this module to production SYS1.NUCLEUS and give an LLA refresh? Just trying to see if an IPL can be avoided. Or an IPL is what needs to be done ? Any suggestions based on your experience will help me. Regards Peter On Sun, 26 Oct 2025, 09:42 Peter, <[email protected]> wrote: > Hello > > I have applied maintenance for zos 2.4 to support and ipled it. > > There was no error during weekend, but during weekdays it started > reporting filling of logrec frequently. > > I dont see any error messages in syslogs as well. > > Any other places I can look into it > > Peter > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
