This is what I could find,

IKJ56646I IKJEFRAF FAILED - RETURN CODE return_code.
Explanation:


IKJEFRAF passed an unexpected return code to IKJEFT01. The UPT, and other
information associated with the user id could not be obtained. This message
will be followed by IKJ56644, which indicates that the default user
attributes will be used.


Detected by:IKJEFT01


Program:TMP



Regards,

Neil Haley
nha...@ca.ibm.com
Storage & Software Mainframe Support
http://www.ibm.com/systems/z/ | http://www.about.me/NeilHaley




From:   "Richards, Robert B." <robert.richa...@opm.gov>
To:     IBM-MAIN@listserv.ua.edu,
Date:   07/12/2013 07:10
Subject:        TSOLOGON TERMINATED. IKJEFRAF ERROR 016
Sent by:        IBM Mainframe Discussion List <IBM-MAIN@listserv.ua.edu>



Has anyone seen this error before and found that it is *not* that the RACF
subsystem had not been started/activated (per SIS search in IBMLINK)?

Any clue would be helpful. Seeing this on a new standalone lpar on a brand
new zEC12.

Was working yesterday. IPL'ed...no joy...same problem.


Bob


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,