DEF NVSAM                     -                                     
     (NAME(SYS1.VVDS.VPROM56)  -                                      
       DEVT(3390)                    -                                
       VOL(PROM56)
       Recatalog ) -                                                 
       CATALOG(SYS1.ICFCAT.SYSPRM)                                  

_________________________________________________________________
Dave Jousma
Assistant Vice President, Mainframe Engineering
david.jou...@53.com
1830 East Paris, Grand Rapids, MIĀ  49546 MD RSCB2H
p 616.653.8429
f 616.653.2717



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of willie bunter
Sent: Wednesday, July 02, 2014 9:04 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: IDCAMS QUESTION - RECATALOG

Good Day,

Can you spot my error.  I am trying to define the VVDS to a specif USERCAT.  Is 
the RECATALOG option allowed?

DEF NVSAM                     -                                     
     (NAME(SYS1.VVDS.VPROM56)  -                                      
       DEVT(3390)                    -                                
       VOL(PROM56)
       Recatalog ) -                                                 
       CATALOG(SYS1.ICFCAT.SYSPRM)                                  
                                                           
IDC3211I KEYWORD 'RECATALOG' IS IMPROPER                              
IDC3202I ABOVE TEXT BYPASSED UNTIL NEXT COMMAND. CONDITION CODE IS 12 
                                                                      
IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 12    

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

This e-mail transmission contains information that is confidential and may be 
privileged.   It is intended only for the addressee(s) named above. If you 
receive this e-mail in error, please do not read, copy or disseminate it in any 
manner. If you are not the intended recipient, any disclosure, copying, 
distribution or use of the contents of this information is prohibited. Please 
reply to the message immediately by informing the sender that the message was 
misdirected. After replying, please erase it from your computer system. Your 
assistance in correcting this error is appreciated.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to