Thanks! Regarding 2: I restored the dataset to another name and then did 2 renames. IEBPDSE did not report any problems.
Best Regards, Thomas Berg ___________________________________________________________________ Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) Interactive is 'manual.' Batch is 'automatic.' > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On > Behalf Of > Hank Oerlemans > Sent: Tuesday, May 26, 2015 8:14 AM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: Corrupt PDSE - IGW699I PDSE Directory Validation Unsuccessful > > I've had to deal with a couple of PDSE issues with z/OS 2.1 and Fault > Analyzer. > > 1. Ensure all systems are up to date with PDSE maintenance > 2. It's possible that IEBPDSE (the z/OS 2.1 version) against your restored > PDSE will still report problems. Reallocate your PDSE and copy (IEBCOPY) > the backup data into it. z/OS 2.1 is more robust about reporting some > internal PDSE issues than previous z/OS levels. If you don't reallocate > you are simply continuing the internal structural problems. > 3. Send your diagnostic data and dumps into IBM to be sure you don't have > something new . > > Regards Hank Oerlemans, > IBM Fault Analyzer > > > > > From: Thomas Berg <thomas.b...@swedbank.se> > To: IBM-MAIN@LISTSERV.UA.EDU > Date: 26/05/2015 11:48 > Subject: Re: Corrupt PDSE - IGW699I PDSE Directory Validation > Unsuccessful > Sent by: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> > > > > BTW, we are on zOS 2.1 in the DEV system and zOS 1.13 in the prod system. > > > > Best Regards, > Thomas Berg > ___________________________________________________________________ > Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) > > Interactive is 'manual.' Batch is 'automatic.' > > > > > > -----Original Message----- > > From: Thomas Berg > > Sent: Tuesday, May 26, 2015 3:46 AM > > To: 'IBM Mainframe Discussion List' > > Subject: RE: Corrupt PDSE - IGW699I PDSE Directory Validation > Unsuccessful > > > > Did run IEBPDSE, but no new info compared to the abend result I posted > below: > > > > IGW699I PDSE Directory Validation Unsuccessful > > DESC:PDSE structure is corrupted > > ERROR NUM:103 > > DSN:SYS6.IDI.PROD5.HIST.FEL > > VOLSER:GEM040 > > ADPages:10169 IXRecords:405168 > > ADPagesInCore:3 ADPagesRead:10166 > > ADTreeLevels:3 > > NDPages:21 IXRecords:2460 > > NDPagesInCore:1 NDPagesRead:20 > > NDTreeLevels:2 > > AD ND Tree Nodes:2430 > > Version:1 > > Orphan Pages:4682 > > RC:4 RS:01188012 > > IGW702I PDSE Directory Validation Unsuccessful > > DESC:<AD> Structure is corrupted > > LTK:D561C14040404040404040404040404040404040 > > ERROR NUM:1 > > DSN:SYS6.IDI.PROD5.HIST.FEL > > VOLSER:GEM040 > > RC:4 RS:01188012 R14:0876C2A4 > > RPN:N/A > > VPTVFN:N/A > > > > > > > > > > Best Regards, > > Thomas Berg > > ___________________________________________________________________ > > Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) > > > > Interactive is 'manual.' Batch is 'automatic.' > > > > > > > > > > > -----Original Message----- > > > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of > > > Mark Jacobs - Listserv > > > Sent: Tuesday, May 26, 2015 3:27 AM > > > To: IBM-MAIN@LISTSERV.UA.EDU > > > Subject: Re: Corrupt PDSE - IGW699I PDSE Directory Validation > Unsuccessful > > > > > > If you take a physical dump of the dataset and send it into IBM for > > > analysis they might be able to get to the root cause. Assuming you're > on > > > zOS 1.13 or higher did you execute IEBPDSE against the restored > dataset > > > to verify its structure? > > > > > > Mark Jacobs > > > > > > > Thomas Berg <mailto:thomas.b...@swedbank.se> > > > > May 25, 2015 at 9:23 PM > > > > AFAIK it should have a very low probability. This due to that those > > > > that can access from outside of the Sysplex (special sysprogs) have > > > > neither reason or interest of doing that. And this is 3.00 AM here. > > > > (At least the operator I spoke to had no knowledge of anyone else > that > > > > me working at this time.) > > > > > > > > I have restored a backup from yesterday now so the immediate problem > > > > is solved. (And saved the corrupted PDSE in case anyone except me is > > > > interested.) > > > > > > > > > > > > > > > > Best Regards, > > > > Thomas Berg > > > > ___________________________________________________________________ > > > > Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) > > > > > > > > Interactive is 'manual.' Batch is 'automatic.' > > > > > > > > > > > > > > > > > ---------------------------------------------------------------------- > > > > For IBM-MAIN subscribe / signoff / archive access instructions, > > > > send email to lists...@listserv.ua.edu with the message: INFO > IBM-MAIN > > > > Mark Jacobs - Listserv <mailto:mark.jac...@custserv.com> > > > > May 25, 2015 at 9:09 PM > > > > Could it have been shared(R/W) outside of a sysplex boundary? > > > > > > > > Mark Jacobs > > > > > > > > > > > > Thomas Berg <mailto:thomas.b...@swedbank.se> > > > > May 25, 2015 at 8:43 PM > > > > Got a corrupt PDSE. Will throw the problem at some of the > responsible > > > > sysprogs. > > > > But in the meantime I wonder if any of the esteem members of this > list > > > > can give some hints leading to the cause. > > > > > > > > Got this when tying a browse from ISPF 3.4 (linecmd B): > > > > > > > > IGW699I PDSE Directory Validation Unsuccessful > > > > DESC:PDSE structure is corrupted > > > > ERROR NUM:103 > > > > DSN:SYS6.IDI.PROD5.HIST > > > > VOLSER:GEM040 > > > > ADPages:10169 IXRecords:405168 > > > > ADPagesInCore:159 ADPagesRead:10010 > > > > ADTreeLevels:3 > > > > NDPages:21 IXRecords:2460 > > > > NDPagesInCore:7 NDPagesRead:14 > > > > NDTreeLevels:2 > > > > AD ND Tree Nodes:2430 > > > > Version:1 > > > > Orphan Pages:4682 > > > > RC:4 RS:01188012 > > > > IGW702I PDSE Directory Validation Unsuccessful > > > > DESC:<AD> Structure is corrupted > > > > LTK:D561C14040404040404040404040404040404040 > > > > IEA995I SYMPTOM DUMP OUTPUT > > > > SYSTEM COMPLETION CODE=0F4 REASON CODE=00000024 > > > > TIME=02.28.25 SEQ=58662 CPU=0000 ASID=0457 > > > > PSW AT TIME OF ERROR 075C1000 888B9690 ILC 2 INTC 0D > > > > NO ACTIVE MODULE FOUND - PRIMARY NOT EQUAL TO HOME > > > > NAME=UNKNOWN > > > > DATA AT PSW 088B968A - 58F05048 0A0DB219 0000A788 > > > > AR/GR 0: 007FF6C8/01188012 1: 00000000/040F4000 > > > > 2: 00000001/00FDB9A0 3: 00000000/7B1A2268 > > > > 4: 00000002/00007703 5: 00000000/7B1A7400 > > > > 6: 00000000/7B1A2060 7: 00000000/00FE0548 > > > > 8: 00000000/00FE05B8 9: 00000001/7B1A2268 > > > > A: 00000000/7B1A7868 B: 00000000/00000000 > > > > C: 00000000/088B9012 D: 00000000/7B1A7778 > > > > E: 00000000/888B9682 F: 00000000/00000024 > > > > END OF SYMPTOM DUMP > > > > ERROR NUM:1 > > > > DSN:SYS6.IDI.PROD5.HIST > > > > VOLSER:GEM040 > > > > RC:4 RS:01188012 R14:0876C2A4 > > > > RPN:N/A > > > > VPTVFN:N/A > > > > IEC036I 002-A4,IGC0005E,S000TBE,KAT30,ISP02264,786B,GEM040, > > > > SYS6.IDI.PROD5.HIST > > > > ERROR DESCRIPTION: IEC036I > > > > Unable to complete the READ against the PDSE directory due to an > error > > > > return code from the SMS service used to obtain directory > information. > > > > END ERROR DESCRIPTION: IEC036I > > > > IRX0250E System abend code 002, reason code 00000164. > > > > IRX0255E Abend in host command SELECT or address environment routine > > > > ISPEXEC. > > > > *** > > > > > > > > > > > > The dataset is a Fault Analyzer dump pdse. Is populated from > > > > productions abends (in another system - same Sysplex). > > > > Was browsing from the dev system. We have 7 other similar datasets, > > > > all populated from the prod system and mostly viewed from the dev > > > > system. First time for me of a corrupt PDSE causing an abend like > this. > > > > > > > > > > > > > > > > Best Regards, > > > > Thomas Berg > > > > ___________________________________________________________________ > > > > Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) > > > > > > > > Interactive is 'manual.' Batch is 'automatic.' > > > > > > > > > ---------------------------------------------------------------------- > > > > For IBM-MAIN subscribe / signoff / archive access instructions, > > > > send email to lists...@listserv.ua.edu with the message: INFO > IBM-MAIN > > > > > > > > > > > > Please be alert for any emails that may ask you for login > information > > > > or directs you to login via a link. If you believe this message is a > > > > phish or aren't sure whether this message is trustworthy, please > send > > > > the original message as an attachment to 'phish...@timeinc.com'. > > > > > > > > > > -- > > > > > > Mark Jacobs > > > Time Customer Service > > > Technology and Product Engineering > > > > > > The standard you walk past is the standard you accept. > > > Lt. Gen. David Morrison > > > > > > ---------------------------------------------------------------------- > > > For IBM-MAIN subscribe / signoff / archive access instructions, > > > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN