Look for something that looks like this CEE3DMP V1 R12.0: Plidump called from error On-unit 07/16/10 11:45:20 AM Page: 1 ASID: 003E Job ID: JOB21950 Job name: LEDGSMP1 Step name: GO UserID: HEALY CEE3845I CEEDUMP Processing started. PLIDUMP was called from statement number 6 at offset +000000D6 from ERR ON-unit with entry address 20900C58 Information for enclave EXAMPLE Information for thread 8000000000000000 Traceback: DSA Entry E Offset Statement Load Mod Program Unit Service Status 1 CEEKKMRA +0000081C CEEPLPKA CEEKKMRA D1908 Call 2 IBMRKDM +000000C2 IBMREV10 IBMRKDM Call 3 ERR ON-unit+000000D6 6 EXAMPLE EXAMPLE Call 4 IBMRERPL +0000065A IBMRLIB1 IBMRERPL Call 5 CEEEV010 +0000013A IBMREV10 CEEEV010 Call 6 CEEHDSP +000017D0 CEEPLPKA CEEHDSP D1908 Call 7 IBMRERRI +0000045A IBMRLIB1 IBMRERRI Exception
Lizette > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On > Behalf Of Lizette Koehler > Sent: Thursday, October 29, 2015 10:58 AM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: U0493 abends > > In the output of the job/stc there should be a CEE DD name which has the trace. > > Lizette > > > > -----Original Message----- > > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > > On Behalf Of Tim Brown > > Sent: Thursday, October 29, 2015 9:36 AM > > To: IBM-MAIN@LISTSERV.UA.EDU > > Subject: Re: U0493 abends > > > > Just > > > > CEE3798I ATTEMPTING TO TAKE A DUMP FOR ABEND U4093 TO DATA SET: > > CAP.D302.T02000 CEE3797I LANGUAGE ENVIRONMENT HAS DYNAMICALLY > CREATED > > A DUMP. > > > > Where do I get CEE trace? > > > > Tim > > > > -----Original Message----- > > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > > On Behalf Of Lizette Koehler > > Sent: Thursday, 29 October, 2015 9:55 AM > > To: IBM-MAIN@LISTSERV.UA.EDU > > Subject: Re: U0493 abends > > > > What CEE messages did you see in the trace? > > Did you get CEE5101C > > > > Please provide the cee trace (probably first 50 lines would be good. > > > > Need to see the TRACE and any additional CEE messages. > > > > This is the source trace not the actual SYSMDUMP or SYSUDUMP text. > > Clear > text > > summary dump. > > > > Lizette > > > > > > > -----Original Message----- > > > From: IBM Mainframe Discussion List > > > [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Tim Brown > > > Sent: Thursday, October 29, 2015 4:28 AM > > > To: IBM-MAIN@LISTSERV.UA.EDU > > > Subject: U0493 abends > > > > > > Starting to get U4903 abends with FTP steps, will be calling support > > > but has > > anyone > > > seen this > > > > > > > > > CEE3798I ATTEMPTING TO TAKE A DUMP FOR ABEND U4093 TO DATA SET: > > > CAP.D302.T0200069.CAP97G55 IGD101I SMS ALLOCATED TO DDNAME > > > (SYS00001) > > > 474 > > > DSN (CAP.D302.T0200069.CAP97G55 ) > > > STORCLAS (PRODSC) MGMTCLAS ( ) DATACLAS ( ) > > > VOL SER NOS= PRODS2 > > > IGD104I CAP.D302.T0200069.CAP97G55 RETAINED, > > DDNAME=SYS00001 > > > IEA822I COMPLETE TRANSACTION DUMP WRITTEN TO > > > CAP.D302.T0200069.CAP97G55 CEE3797I LANGUAGE ENVIRONMENT HAS > > > DYNAMICALLY CREATED A DUMP. > > > IEA995I SYMPTOM DUMP OUTPUT 514 > > > USER COMPLETION CODE=4093 REASON CODE=00000090 > > > TIME=02.00.06 SEQ=04204 CPU=0000 ASID=0042 > > > PSW AT TIME OF ERROR 078D1000 80008EBC ILC 2 INTC 0D > > > ACTIVE LOAD MODULE ADDRESS=00007158 OFFSET=00001D64 > > > > > > Thanks, > > > Tim Brown > > > Supervisor Computer Operations > > > Central Hudson Gas & Electric > > > 284 South Ave > > > Poughkeepsie, NY 12601 > > > Email: tbr...@cenhud.com <<mailto:tbr...@cenhud.com>> > > > Phone: 845-486-5643 > > > Fax: 845-486-5921 > > > Cell: 845-235-4255 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN