OK, I know that there can be multiple TIOTs in a single address space. I
know this because the documentation the IEFUJI says that it can do I/O to a
data set either by doing a DYNALLOC on it, or by putting the DD in the
initiator procedure.

So, have you ever wanted to run multiple, concurrent, executions of some
program which does not accept an alternative DD name list? For instance,
some in-house COBOL program. Wouldn't it be kind of nice to be able to
specify some parameter, such as NEWTIOT=YES so that the program being
attached would have its own, "private" TIOT & XTIOT, which would then
propogate to any of its children TCBs which did not have a NEWTIOT=YES.
Hum, it might even be nice to be able to list which DDs are to be "passed
down", a bit like you can say whether or not to share a specific SUBPOOL
with a subtask. That might be nice for something like SYSPRINT.

Just running the idea up the flag pole to see who salutes. I don't really
have much else to do any more. Just waiting for the axe.

-- 
There’s no obfuscated Perl contest because it’s pointless.

—Jeff Polk