SETRP, IIRC, always "returns to the next sequential instruction" unless you specify the REGS parameter.
One thing that I think you can't do is to set the "DUMP = Yes" option (or any other option for that matter) without also setting the "return code", as all the expansions set that, and the return code setting defaults to "continue with termination" (i.e., percolate). Thus it is often a good idea to set all the options (in one or more invocations) and then request retry last, to avoid resetting the return code from "retry" to "percolate". Peter Relson z/OS Core Technology Design ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN