On 27/04/2017 12:46 AM, Tom Marchant wrote:
This sounds similar to a problem that I had a while back. Do you have
OA47958 applied?

It is applied, however it is very interesting, including the very similar JCL for testing.

Unfortunately, if I take their JCL and add some variation:

//PROC1     PROC PPP=
//          EXPORT SYMLIST=QQQ
//          SET QQQ=&PPP
//PSTEP1    EXEC PGM=IEBGENER
//SYSPRINT  DD   DUMMY
//SYSUT1    DD *,SYMBOLS=JCLONLY
SYMBOL QQQ=&QQQ
/*
//SYSUT2    DD   SYSOUT=*
//SYSIN     DD   DUMMY
//          PEND
//JSTEP1    EXEC PROC1,PPP=VALUE1
//JSTEP2    EXEC PROC1,PPP=VALUE2
//JSTEP3    EXEC PROC1,PPP=VALUE3
//JSTEP4    EXEC PROC1
//JSTEP5    EXEC PROC1,PPP=VALUE5

I get the output:

SYMBOL QQQ=VALUE1
SYMBOL QQQ=VALUE2
SYMBOL QQQ=
SYMBOL QQQ=
SYMBOL QQQ=VALUE5

That still looks broken. Where did VALUE3 go?

--
Andrew Rowley
Black Hill Software
+61 413 302 386

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to