Art, What about running a second JES2 system on where a production JES2 is already running? It can totally separate from the JES2 production system. And on that test JES2 system you can try removing the PRT and RMT definitian and see what happens. Scott
On Wednesday, May 17, 2017 2:04 PM, Art Gutowski <arthur.gutow...@gm.com> wrote: Since the JES2-L list seems to be defunct, and I have not found a conclusive answer in the archives nor the books, I'd like to know if a single-member warm-start is sufficient to remove PRT(xxx) and RMT(xxx) definitions from a MAS, or whether an all-member warm-start is required. The complex in question is a 3-system MAS. I don't have, at present, a representative test environment to play in. The requirements for adding and modifying these elements are well-documented, requirements for delete are not explicit, IMO. If I have overlooked a passage, please correct my misunderstanding. I did find a couple of short threads where this question was asked, and I see "seems to" and "assume". but nothing that says "I tried it and it works". Does the venerable Mr. Wasik monitor this list? Thanks, Art Gutowski General Motors, LLC ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN