Whether ACTION or DOC, these instructions need to be qualified many times over. 
IBM occasionally PEs a PTF over some problem with HOLD data--usually when it's 
missing. There may be nothing wrong with the code, just the packaging and 
accompanying--or not--documentation. 

I'm obviously perturbed in this case because we're trying to simply the 
platform for a new generation. In particular, that's one of the main goals of 
z/OSMF, for which this sysmod was created. Like tossing a grenade to a kid with 
the directive to pull the pin or not--as you choose.

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
robin...@sce.com


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Tom Marchant
Sent: Thursday, May 18, 2017 1:34 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: (External):Re: Mischaracterized HOLDDATA

On Thu, 18 May 2017 14:14:10 -0600, Paul Gilmartin wrote:

>Can IBM repair this even after the fact?  I know SMPHOLD may contain
>++HOLD ... ACTION.  But I doubt that LIST ERRSYSMODS will show it,

Do you mean LIST HOLDERROR? or perhaps REPORT ERRSYSMODS?
Either way, it will not. Doc and Action holds are System holds, not Error 
Holds. 
You could use LIST HOLDSYSTEM.

>so it does little to alert the programmer who relies on ERRSYSMODS 
>after APPLY and before deployment.

Relying on ERROR holds to know about SYSTEM holds would be a foolish thing to 
do.
Especially if you mean an ERRSYSMODS Report. That only reports on unresolved 
error holds.

>
>I could envision a ++HOLD ... ERROR resolved by a trivial PTF with
>the corrected ++HOLD ... ACTION.  Ugh.

Sure, the PTF with an incorrect SYSTEM hold could have an ERROR hold
 and a resolving PTF with an updated SYSTEM hold. That could be an 
appropriate thing to do.

-- 
Tom Marchant


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to