I wouldn't go so far as to say don't use JOBLIB :)

But, I'll bet that whatever level of RPG this is, doesn't fully understand 
PSE/E....

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU]
> On Behalf Of Wayne Bickerdike
> Sent: Monday, July 23, 2018 1:41 PM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Re: IEC020I 001-4 question
> 
> So it's a PDSE.
> 
> Going back at least 40 years, one golden rule. Don't use JOBLIB......
> 
> On Tue, Jul 24, 2018 at 6:32 AM, Tony Thigpen <t...@vse2pdf.com> wrote:
> 
> > Data Set Name  . . . : TST.COMPILE.LIBRARY
> >
> > General Data                          Current Allocation
> >  Management class . . : **None**       Allocated cylinders : 434
> >  Storage class  . . . : **None**       Allocated extents . : 1
> >   Volume serial . . . : HKYSY0         Maximum dir. blocks : NOLIMIT
> >   Device type . . . . : 3390
> >  Data class . . . . . : **None**
> >   Organization  . . . : PO            Current Utilization
> >   Record format . . . : U              Used pages  . . . . : 16,592
> >   Record length . . . : 0              % Utilized  . . . . : 21
> >   Block size  . . . . : 7040           Number of members . : 1,756
> >   1st extent cylinders: 434
> >   Secondary cylinders : 0
> >   Data set name type  : LIBRARY       Dates
> >                                        Creation date . . . : 2004/05/11
> >                                        Referenced date . . :
> > 2018/07/23
> >
> > Tony Thigpen
> >
> >
> > Gibney, Dave wrote on 07/23/2018 02:48 PM:
> >
> >> Taking wagers that it's a PDS/E?
> >>
> >> -----Original Message-----
> >>> From: IBM Mainframe Discussion List
> >>> [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Tony Thigpen
> >>> Sent: Monday, July 23, 2018 11:45 AM
> >>> To: IBM-MAIN@LISTSERV.UA.EDU
> >>> Subject: Re: IEC020I 001-4 question
> >>>
> >>> Found something. Doing more research, but thought I would provide
> >>> the info in case it rings anyone's bell.
> >>>
> >>> The only jobs that have this problem, also have a test library in
> >>> the JOBLIB. If the test library is removed, then the RPG works fine.
> >>>
> >>> Fails:
> >>> //JOBLIB   DD DSN=TST.COMPILE.LIBRARY,DISP=SHR
> >>> //         DD DSN=PRD.COMPILE.LIBRARY,DISP=SHR
> >>> Works:
> >>> //JOBLIB   DD DSN=PRD.COMPILE.LIBRARY,DISP=SHR
> >>>
> >>> Tony Thigpen
> >>>
> >>> Tony Thigpen wrote on 07/23/2018 01:52 PM:
> >>>
> >>>> See below
> >>>>
> >>>> Tony Thigpen
> >>>>
> >>>> Lizette Koehler wrote on 07/23/2018 01:43 PM:
> >>>>
> >>>>> Could they try another utility like SORT on the file to see if the
> >>>>> same error occurs?
> >>>>>
> >>>> Will try this
> >>>>
> >>>> When the error occurs, do they rerun the job and still get the same
> >>>>> error?
> >>>>>
> >>>> If fails during the rerun. The only way they were able to get it to
> >>>> run is replace the RPG with Natural.
> >>>>
> >>>> Is it always shop written programs that get the IEC020I error?
> >>>>>
> >>>> Always RPG. I will shortly try some IBM utilities.
> >>>>
> >>>> Do these programs have a common subroutine reading files?
> >>>>>
> >>>> No subroutines. All basic RPG.
> >>>>
> >>>> Does the error occur when there is data or when there is no data?
> >>>>>
> >>>> I need to ask them about this.
> >>>>
> >>>> Probably more questions than answers
> >>>>>
> >>>> Yep. But thanks for the starting points. I will post the results.
> >>>>
> >>>> Lizette
> >>>>>
> >>>>>
> >>>>> -----Original Message-----
> >>>>>> From: IBM Mainframe Discussion List <IBM-
> m...@listserv.ua.edu> On
> >>>>>> Behalf Of Tony Thigpen
> >>>>>> Sent: Monday, July 23, 2018 9:13 AM
> >>>>>> To: IBM-MAIN@LISTSERV.UA.EDU
> >>>>>> Subject: IEC020I 001-4 question
> >>>>>>
> >>>>>> I have a site with a bunch of old RPG programs. Lately, it seems
> >>>>>> that sometimes the get the following. Once it happens, they can
> >>>>>> not get the program to ever run correctly again, even after re-
> compiling.
> >>>>>>
> >>>>>> IEC020I 001-4,HSR003B,STEP0017,STYWRK,1818,HKYP05,
> >>>>>> IEC020I PROD.HKY.WORK.HSR003B.WK1.S050 IEC020I DCB
> EROPT=ABE OR
> >>>>>> AN INVALID CODE, AND/OR NO SYNAD EXIT
> >>>>>>
> >>>>> SPECIFIED
> >>>
> >>>>
> >>>>>> We have a contractor working on 'performance issues' with this
> >>>>>> machine, and I am wondering if he has changed something. The
> >>>>>> customer is just now telling us, but they say it happens every
> >>>>>> few weeks to a different program.
> >>>>>> Usually,
> >>>>>> the programs are simple, so they are just rewriting them in Natural.
> >>>>>>
> >>>>>> Fridays problem program was very simple:
> >>>>>> FSTYWRK  UP  F9000 300            DISK40
> >>>>>> ISTYWRK  NS  01
> >>>>>> I                                      100 100 ALTCLS
> >>>>>> C           ALTCLS    COMP ' '                  25
> >>>>>> OSTYWRK  D        01
> >>>>>> O                                   71 '0'
> >>>>>> O                 25                72 '09'
> >>>>>>
> >>>>>> //STEP0017 EXEC PGM=HAO07E,PARM='DATE=$WEDATE',
> >>>>>> //         COND=(3,LT)
> >>>>>> //STYWRK   DD DSN=PROD.HKY.WORK.HSR003B.WK1.S050,
> >>>>>> //         DISP=(OLD,KEEP,KEEP)
> >>>>>> //SYSUDUMP DD SYSOUT=*
> >>>>>> //SYSPRINT DD SYSOUT=*
> >>>>>> /*
> >>>>>>
> >>>>>> Any suggestions? Questions?
> >>>>>>
> >>>>>> --
> >>>>>> Tony Thigpen
> >>>>>>
> >>>>>
> >>>>> ------------------------------------------------------------------
> >>>>> ---- For IBM-MAIN subscribe / signoff / archive access
> >>>>> instructions, send email to lists...@listserv.ua.edu with the
> >>>>> message: INFO IBM-MAIN
> >>>>>
> >>>>>
> >>>>>
> >>>> -------------------------------------------------------------------
> >>>> --- For IBM-MAIN subscribe / signoff / archive access instructions,
> >>>> send email to lists...@listserv.ua.edu with the message: INFO
> >>>> IBM-MAIN
> >>>>
> >>>>
> >>>>
> >>> --------------------------------------------------------------------
> >>> -- For IBM-MAIN subscribe / signoff / archive access instructions,
> >>> send email to lists...@listserv.ua.edu with the message: INFO
> >>> IBM-MAIN
> >>>
> >>
> >> ---------------------------------------------------------------------
> >> - For IBM-MAIN subscribe / signoff / archive access instructions,
> >> send email to lists...@listserv.ua.edu with the message: INFO
> >> IBM-MAIN
> >>
> >>
> >>
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> > email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> >
> 
> 
> 
> --
> Wayne V. Bickerdike
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to
> lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN